Application
Home - Application - Solar Energy - Module Breakage Tester
16

Module Breakage Tester

Module breakage tester is used to provide confidence that the risk of physical injuries can be minimized if the PV module is broken in its specified installation. The module breakage test is specified in the IEC 61730 (MST 32)

Test Standard

Testing Method

IEC61730-2

MST 32

Module breakage test

Component fixture: 
1. Frame pressure block fixing method: Simulate the actual installation method. 
Double glass component fixing method: Special fixture for double glass components. 
2. After the impact bag is suspended, it should not exceed 13mm from the surface of the component, and not exceed 50mm from the center of the component. 
3. Impact bag: Filled with lead bullets of approximately 45.5±0.5kg in weight and 2.5~3.0mm in diameter (No. 7.5). 
4. Shrapnel bag lifting and releasing: Electric and pneumatic. 
5. Drop height: 300, 450, 1220mm Note: The impact point is at the center of the component. 
6. Anti-secondary impact function: Automatic reset. Protection: Single-sided organic glass protective barrier. 
Call me!