1. Technical Parameter
Impulse Voltage Generator: 1.2μs (±30%) 
Positive pulse width: 50μs (±20%) 
Voltage peak value: ±3% 
Polarity: positive/negative 
Load conditions: various types of pF~nF level components, mainstream crystalline silicon modules, bifacial modules, shingled modules, PERC modules, half-cut modules, CIGS modules, etc. 
2. Reinforced insulation: 
Highest impulse voltage: approximately 30KV 
Note: Designed according to the load + system voltage 1500V + reinforced insulation + altitude factor 6001~7000m. Altitude factor refers to the 6001~7000m defined in IEC 61730-1:2016, with a reinforcement factor of 1.95. 
3. Voltage display accuracy: 0.01KV 
4. Surge output mode: manual, automatic (switchable) 
5. Surge times: single, continuous (adjustable) 
6. Surge interval: adjustable 
7. Software and hardware parts: 
Chinese operating software 
Large display monitor Load matching unit, switch different capacitive components, plug and socket connection method 
Oscilloscope: 1 set, displays waveform 
High Voltage Probe (P6039A or negotiable): attenuation ratio 1000:1, pulse voltage <27KVp-p 
Electrical control cabinet