IPX9K High Temperature Pressure Jet Waterproof Test Chamber

IPX9K High Temperature Pressure Jet Waterproof Test Chamber

IPX9K high temperature pressure jet waterproof test chamber is an Ingress Protection rating system test that verifies a product is protected against close-range high pressure, high temperature liquid sprays.  
Model MT-HTP512 MT-HTP1000
Workspace Volume(L) 512 1000
Workspace dims.(mm) Width 800 1000
Deep 800 1000
Height 800 1000
External dims. (mm) Width 1550 1550
Deep 1370 1560
Height 2170 2170
Performance Spray nozzles Diameter 12.5mm
Quantity 4 pcs for 4 angels (0°,30°,60°,90°)
Turntable Height adjustable
Rotating speed 1~5 rpm
Diameter Φ400mm
Load-bearing ≤20kg
Test distance From jet nozzle to the surface of the test unit: 100~150mm
Test time 30 seconds in each positions (0°, 30°, 60° & 90°) , totally 120s
Watr flow (L/min) 14~16 L / min
Water temperature RT~ 80°/± 5°C
Water pressure 80 – 100 bar
Construction Material Exterior A3 Steel board with powder coated
Interior Mirror Stainless Steel-SUS#304
Viewing window Tempered glasses
Control system Controller 7" color touch-screen
Timing range 1~9999 (H.M.S)adjustable
Water circulation system Water tank: 100L(Could heat the water temperature to 90°C)
Water cyclic utilization to save engergy
"Facility requriement" Inlet water Type City tap water
Pressure ≥0.7kgf/cm2
Temperature RT
Electricity Power suuply 3 phase 50HZ/60HZ
Voltage (VAC) and frequency (Hz) dependant on country/region of installation.
Accessories Fuses; Drain-pipe
Safety protection Motor overload;
Short-circuit protection
Leakage protection etc.
Description

Ipx9k high temperature pressure jet waterproof test chamber is an Ingress Protection rating system test that verifies a product is protected against close-range high pressure, high temperature liquid sprays.

In this construction 4 jet nozzles are provided with solenoid control, change over relays and logic control that is fed with water at a temperature of 80°C water and a pressure of 8–10 Mpa (80–100 bar). The water flows at the flow rate of 14–16 l/min. It should be noted that the nozzles should be held at 10 cm –15 cm from the specimen for 30 seconds at different angles of 0°, 30°, 60° and 90°. It also comes with optional accessories such as a tilting test table placed at the center of the cabinet. The unit under test is fixed on the rotating table for the uniform distribution of water on all sides. An enclosure of Acrylic and Aluminum is also provided on demand.


Features
High quality interior stainless steel (SUS#304)
7’’ touch screen and PLC core control component, easy to operation and control
High quality stepping motor, set the speed and angle by touch screen.
PID temperature control, set the temperature by touch screen.
Test time: 0-999m adjustment, auto stop.